Heated towel rails manufactured by Rutland London have been independently type tested to confirm their essential performance characteristics in accordance with EN 442 and other key harmonised standards.
When purchasing a heated towel rail or radiator, care should always be taken to ensure the product is compliant with the relevant directives and standards. Non-compliant products from other manufacturers are likely to be inefficient and could possibly be dangerous.
Essential Characteristics (EN 442):
Characteristic: |
Performance: |
Reaction to fire: |
A1 |
Release of dangerous substances: |
None |
Pressure tightness: |
No leakage at 1,3 x MOP [520 kPa] |
Surface temperature: |
Maximum 85°C
|
Resistance to pressure: |
No breakage at 1,69 x MOP [520 kPa]
|
Resistance against corrosion: |
No corrosion after 100 h humidity |
Resistance against minor impact: |
ISO 2409:2013-1A-0 |
Heat Outputs (EN 442):
Size (mm): |
Standard rated thermal output Φ50 (W): |
952 (H) x 500 (W) x 138 (D) |
144
|
952 (H) x 685 (W) x 138 (D) |
168
|
952 (H) x 837 (W) x 138 (D) |
188
|
952 (H) x 989 (W) x 138 (D)
|
208
|
The above technical information is based on the towel rail being supplied in a polished or brushed finish and configured for installation on a central heating system.
Bespoke sizes will have no performance declared ("NPD") for heat output unless stated otherwise. Should a heat output be required for a bespoke size, a non-refundable deposit will be required.
Electric Only / Dual Fuel Configurations:
When supplied in either an electric only or dual fuel heating configuration, this heated towel rail complies with EN 60335-1 & EN 60335-2-43.
Declaration of Performance:
Should you require the Declaration of Performance for this product, please email
sales@rutlandlondon.co.uk or to call +44 (0) 20 7993 6736.