Heated towel rails manufactured by Rutland London have been independently type tested to confirm their
essential performance characteristics in accordance with EN 442 and other key harmonised standards.
When purchasing a heated towel rail or radiator, care should always be taken to ensure the product is
compliant with the relevant directives and standards. Non-compliant products from other manufacturers are
likely to be inefficient and could possibly be dangerous.
Essential Characteristics (EN 442):
Characteristic: |
Performance: |
Reaction to fire: |
A1 |
Release of dangerous substances: |
None |
Pressure tightness: |
No leakage at 1,3 x MOP [520 kPa] |
Surface temperature: |
Maximum 85°C
|
Resistance to pressure: |
No breakage at 1,69 x MOP [520
kPa]
|
Resistance against corrosion: |
No corrosion after 100 h humidity |
Resistance against minor impact: |
ISO 2409:2013-1A-0 |
Heat Outputs (EN 442):
Size (mm): |
Standard rated thermal output Φ50 (W): |
350 (H) x 550 (W) x 125 (D) |
37,7
|
640 (H) x
550 (W) x
125 (D)
|
73,5
|
930 (H) x
550 (W) x
125 (D)
|
124
|
1220 (H) x 550 (W) x 125 (D) |
191 |
1510 (H) x
550 (W) x
125 (D)
|
273 |
1800 (H) x
550 (W) x
125 (D)
|
371 |
The above technical information is based on the towel rail being supplied in a polished or brushed finish and
configured for installation on a central heating system.
Bespoke sizes will have no performance declared ("NPD") for heat output unless stated otherwise. Should a
heat output be required for a bespoke size, a non-refundable deposit will be required.
Electric Only / Dual Fuel Configurations:
When supplied in either an electric only or dual fuel heating configuration, this heated towel rail complies
with EN 60335-1 & EN 60335-2-43.
Declaration of Performance:
Should you require the Declaration of Performance for this product, please email
sales@rutlandlondon.co.uk or